For hydrostatic level measurement on tanks with superimposed pressure, a differential pressure sensor is required for the measurement. Our customized pressure sensor UTD20 offers you a number of advantages. The integrated digital
compensation for pressure and temperature has a ready-to-connect option for signal evaluation in case of non
potentially explosive liquid gas tanks (CO2, nitrogen, etc.).
- Measuring ranges: 0…1.5 bar
- Adjustable measuring range and zero point adjustment
- Accuracy: < ±0.5 % of nominal range (Total Performance)
- Operating range: -40 to +85 °C
- Materials in contact with the process: Stainless steel